XLG-1200W series is a waterproof AC DC LED drive power supply, with constant voltage, constant current, constant power output design, using 180-264VAC input voltage range, the whole series to provide 48V output. Due to its conversion efficiency of up to 94%, it adopts fanless design and can work in the cabinet temperature range of -20℃ to + 60℃ under natural air cooling and heat dissipation. The metal housing and the high IP65 / IP67 design make the XLG-1200W series suitable for indoor or outdoor applications.
Built-in 105 ℃ long-life aluminum electrolytic capacitor. Built-in long-life aluminum electrolytic capacitor provides ultra-low no-load power consumption (less than 0.75W),,which enables the terminal system to easily meet international energy requirements XLG-1200W has complete protection function and anti -3G vibration capability. It conforms to safety regulations such as UL1012 / EN60950-1,and can meet the energy-saving requirements of a new generation of LED lighting,providing a cost-effective solution for various LED lighting.
If you have any questions, please do not hesitate to contact us atEmail: weho@chnwh.com
Model | XLG-1200-48 |
DC Output Voltage | 48V |
Rated Output Current | 25A |
Current Range | 0~25A |
Output Power | 1200W |
Wave and Noise | 240mVp-p |
Voltage Accuracy | ± 2% |
Line Regulation | ± 0.5% |
Load Regulation | ± 0.5% |
Start, Rise, Hold Time | 500ms, 50ms, 24ms/230VAC (at full load) |
Input Voltage Range | 180~264VAC 245~373VDC |
Frequency Range | 47~63Hz |
AC Input Current | 11A/230VAC |
Efficiency | 94.0% |
Impulse Current | Cold start current 65A/230VAC |
Leakage Current | <2mA/240VAC |
Overcurrent Protection | 95%~108% of the rated output current exceeds the current limit to start over-current protection Automatic recovery after abnormal situation is eliminated |
Short Circuit Protection | Protection mode: Hiccup mode: Recover automatically normal output after abnormal conditions are removed |
Overvoltage Protection | 115%~ 135% of rated output voltage startup overvoltage protection |
Protection mode: Hiccup mode: Recover automatically normal output after abnormal conditions are removed | |
Over Temperature Protection | 105℃ ± 5℃ (JK1/JK2 is next to the transformer/MOS tube surface detection) |
Protection mode: Turn Off the output voltage and the normal output can be automatically restored after the temperature drops | |
Working Temperature | -20℃ ~ +60℃ |
Working Humidity | 20% ~ 90% RH, non-condensing |
Storage Temperature and Humidity | -40℃ ~ +85℃;10% ~ 95% RH, non condensing |
Seismic resistance | 10~500Hz, 5G 12min/ 1 cycle, X, Y, Z axes, duration 72 minutes |
Pressure Resistance | I/P~O/P:1.5KVAC I/P~FG:1.5KVAC O/P~FG:0.5KVAC |
Isolation Resistance | I/P~O/P, I/P~FG, O/P~FG: 100M Ohms/500VDC/25℃/70%RH |
Safety Standard | Compliance to UL60950-1, TUV EN60950-1 |
Electromagnetic Compatibility Emission | Compliance to EN55022 Class A |
Electromagnetic Compatibility Immunity | Compliance to EN55024 |
Dimension | 340*120*56mm |
Weight | 3.45kg |