Model | LPV-50-12 | LPV-50-24 | LPV-50-36 | |
Output | DC Voltage | 12V | 24V | 36V |
Voltage Tolerance | ±1% | ±1% | ±1% | |
Rated Current | 4.2A | 2.1A | 1.4A | |
Current Range | 0~4.2A | 0~2.1A | 0~1.4A | |
Rated Power | 50.4W | 50.4W | 50.4W | |
Ripple&Noise | 100mvp-p | 150mvp-p | 180mvp-p | |
Input | Voltage Range | 170~264VAC, 235~373VDC | ||
Frequency | 47~63HZ | |||
AC Current | 0.65A/230VAC | |||
Efficiency | 82% | 84% | 85% | |
Inrush Current | Cold start current 35A/230VAC | |||
Leakage Current | <1mA/240VAC | |||
Protection | Over Load | Rated output power 115%~150% start overload protection | ||
Protection type: hiccup mode, auto-recovery after fault condition is removed | ||||
Over Voltage | 15.6~17.8V | 30.6~33.2V | 42.6~44.2V | |
Protection type: hiccup mode,auto-recovery after fault condition is removed | ||||
Over Temperature | Shell temp≥85°C, start over temperature protection | |||
Protection mode: cutoff output,auto-recovery after temperature becomes normal | ||||
Environment | Working Temp, Humidity | -10°C ~ +60°C, 20%~90%RH | ||
Storage Temp, Humidity | -20°C ~ +85°C, 10%~95%RH non condensing | |||
Withstand Vibration | 10~500HZ, 2G 10min/1cycle, period for 60minutes, each axes | |||
Safety | Withstand Voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | ||
Isolated Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M ohms/500VDC | |||
Fits | Safety Standard | Fit UL1012, IP67 protect level | ||
Standard | EMC Standard | Fit EN55022, CLASS | ||
Others | Dimension | 190*49*34mm (L*W*H) | ||
Weight/Packing | 0.78kg/30pcs/25kg/0.025 m³/0.87CUFT |
Our products have CE ROHS certification to ensure quality.
The product can be cooled by convection of natural air.
The product has completed the 100% full load aging test.
This product is designed for constant voltage.
This product is both low-cost and reliable.