| Model | MDR-100-12 | MDR-100-15 | MDR-100-24 | MDR-100-48 |
| Output | DC Voltage | 12V | 15V | 24V | 48V |
| Rated Current | 7.5A | 6.7A | 4A | 2A |
| Current Range | 0 ~ 7.5A | 0 ~6.7A | 0 -4A | 0-2A |
| Rated Power | 100W | 100W | 100W | 100W |
| Ripple & Noise (max.) | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p |
| Volage ADJ Range | 12 -13.2V | 15-16.5V | 24 – 26.4V | 48 ~ 56V |
| Voltage Tolerance | ±2.0% | ±1.0% | ±1.0% | ±1.0% |
| Line Regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
| Load Regulation | ±1.5% | ±1.0% | ±1.0% | ±1.0% |
| Setup, Rise Time Note.5 | 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load |
| Hold Up Time (Typ.) | 50ms/230VAC 20ms/115VAC at full load |
| Input | Voltage Range | 85~264VAC 120~370VDC |
| Frequency Range | 47 ~ 63Hz |
| Efficiency (Typ.) | 78% | 86% | 88% | 87% |
| AC Current(Typ.) | 1.8A/115VAC 1A/230VAC |
| Inrush Current (Typ.) | Cold start: 30A/115VAC, 60A/230VAC |
| Leakage Current | <1mA/240VAC |
| Protection | Overload | 105% – 150% rated output power |
| Protection type: Constant current limiting, recovers automatically after fault condition is removed |
| Overvoltage | 6.25-7.25V | 15.6 – 18V | 31.2-36V | 57.6 – 64.8V |
| Protection type: Shut down o/p voltage, re-power on to recover |
| Function | DC Signal | Relay contact rating (max.): 30V/1A resistive |
| Environment | Working Humidity | 20% ~ 90%RH non-condensing |
| Storage Temp, Humidity | -40°C ~ +85°C, 10% ~ 95%RH |
| Temp Coefficient | ±0.03%/°C (0 – 50°C) |
| Vibration | Component: 10 – 500Hz, 2G 10min./1 cycle, the period for 60min. each along X, Y, and Z axes; Mounting: Compliance to IEC60068-2-6 |
| Safety & EMC | Safety Standards | UL508, UL60950-1, TUV EN60950-1 approved |
| Withstand Voltage | l/P-0/P: 3KVAC l/P-FG: 2KVAC 0/P-FG: 0.5KVAC |
| Isolation Resistance | l/P-O/P, l/P-FG, 0/P-FG:>100M Ohms/500VDC/25°C/70% RH |
| EMC Emission | Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3 |
| EMC Immunity | Compliance to EN6100(M-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A |
| Others | MTBF | 299.2K hrs min. MIL-HDBK-217F (25°C) |
| Dimension | 50*90*100mm (W*H*D) |
| Packing | 0.42Kg; 30pcs/20Kg/0.82CUFT |
| Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25°C of ambient temperature. |
| 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. |
| 3. Tolerance: includes set up tolerance, line regulation, and load regulation. |
| 4. The power supply is considered a component that will be installed into the final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies. |
| 5. The length of set-up time is measured at the first cold start. Turning ON/OFF the power supply may lead to an increase in the set-up time. |