Model | XLG-25-12 | XLG-25-24 | XLG-25-36 | XLG-25-48 |
DC output voltage | 12V | 24V | 36V | 48V |
Rated output current | 2A | 1A | 0.7A | 0.5A |
Constant current range | 6~12V | 12~24V | 18~36V | 24~48V |
Output power | 24W | 24W | 25W | 24W |
Wave and noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p |
Voltage accuracy | ± 3% | ± 2% | ± 1% | ± 1% |
Line regulation | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% |
Load regulation | ± 2% | ± 1% | ± 0.5% | ± 0.5% |
Start, rise, hold time | 500ms,80ms,16ms/230VAC (at full load) | |||
Input voltage range | 95 ~264VAC,135 ~373VDC | |||
Frequency range | 47 ~ 63Hz | |||
AC input current | 0.28A/230VAC | |||
Efficiency | 86.5% | 87.5% | 87.5% | 88.5% |
Impulse current | Cold start current 25A/230VAC | |||
Leakage current | <1mA/240VAC | |||
Overcurrent protection | 95%~108% of the rated output current starts overcurrent limit, recover automatically after abnormal conditions are removed | |||
Short circuit protection | Hiccup mode: recover automatically normal output after abnormal conditions are removed | |||
Working temperature | -20℃~ +60℃ | |||
Working humidity | 20% ~90% RH, non condensing | |||
Storage temperature and humidity | -40℃~ +85℃;10% ~95% RH,non condensing | |||
Seismic resistance | 10~500Hz,,3G 10min/ 1 cycle,X, Y, Z axes,duration 60 minutes | |||
Pressure resistance | I/P~O/P:1.5KVAC I/P~FG:1.5KVAC O/P~FG:0.5KVAC | |||
Isolation resistance | I/P~O/P,I/P~FG,O/P~FG: 100M Ohms/500VDC/25℃/70%RH | |||
Safety standard | Compliance to UL60950-1,TUV EN60950-1,IP67 | |||
Electromagnetic compatibility emission | Compliance to EN55022 Class A | |||
Electromagnetic compatibility immunity | Compliance to EN55024 | |||
Dimension | 182*30*20mm (L*W*H) | |||
Packing | 0.22kg/80pcs/18.5kg/0.025 cubic meters |