200W Waterproof IP67 Constant Current Switching Power Supply AC 110V 220V DC 12V 24V 36V 48V LED Driver
AC/DC LED Driver Waterproof XLG Series

200W Waterproof IP67 Constant Current Switching Power Supply AC 110V 220V DC 12V 24V 36V 48V LED Driver

XLG-200W adopts the international common AC input voltage range, and the whole series provides 12V, 24V, 36V and 48V outputs. Built-in long-life aluminum electrolytic capacitors provide ultra-low no-load power consumption (less than 0.75W), which can make the terminal system easily meet international energy requirements.

XLG-200W has Short circuit / Overload / Overvoltage / Overtemperature protection function and anti-3G vibration capability. 100% full load burning machine test, with high efficiency, long life and high reliability. It complies with safety regulations such as UL1012 and EN60950-1, and can meet the energy-saving requirements of the new generation of LED lighting, providing a cost-effective solution for various LED lighting.

If you have any questions, please do not hesitate to contact us atEmail: weho@chnwh.com

ModelXLG-200-12XLG-200-24XLG-200-36XLG-200-48
DC output voltage12V24V36V48V
Rated output current16.5A8.3A5.5A4.16A
Current range0~16.5A0~8.3A0~5.5A0~4.16A
Output power198W240W252W250W
Wave and noise180mVp-p200mVp-p220mVp-p220mVp-p
Voltage accuracy± 3%± 2%± 2%± 2%
Line regulation± 0.5%± 0.5%± 0.5%± 0.5%
Load regulation± 2%± 0.5%± 0.5%± 0.5%
Start, rise, hold time200ms,30ms,20ms/230VAC  (at full load)
Input voltage range180 ~264VAC,235 ~373VDC
Frequency range47 ~ 63Hz
AC input current2.5A/230VAC
Efficiency91.0%92.0%92.5%93.0%
Impulse currentCold start current   45A/230VAC
Leakage current<2mA/240VAC
Overcurrent protection95%~108% of the rated output current starts overcurrent limit,
recover automatically after abnormal conditions are removed
Short circuit protectionProtection mode: Hiccup mode: recover automatically normal output after abnormal conditions are removed
Overvoltage protection115%~ 135% of rated output voltage startup overvoltage protection
Protection mode: Hiccup mode: recover automatically normal output after abnormal conditions are removed
Over temperature protection95℃ ±10℃ (JK1 is next to the transformer/MOS tube surface detection)
Protection mode: Turn Off the output voltage,
and the normal output can be automatically restored after the temperature drops
Working temperature-20℃~ +60℃
Working humidity20% ~90% RH, non condensing
Storage temperature and humidity-40℃~ +85℃;10% ~95% RH,non condensing
Seismic resistance10~500Hz,,3G 12min/ 1 cycle,X, Y, Z axes,duration 60 minutes
Pressure resistanceI/P~O/P:1.5KVAC    I/P~FG:1.5KVAC    O/P~FG:0.5KVAC
Isolation resistanceI/P~O/P,I/P~FG,O/P~FG: 100M Ohms/500VDC/25℃/70%RH
Safety standardCompliance to UL60950-1,TUV EN60950-1
Electromagnetic compatibility emissionCompliance to EN55022 Class A
Electromagnetic compatibility immunityCompliance to EN55024
Dimension205*69*43mm (L*W*H)
Packing0.85kg/16pcs/14kg/0.026 cubic meters

Dimensions 8